描述
Gaskleen Light filter assemblies have been designed specifically to provide the high-purity gas filtration required in solar cell and liquid crystal display manufacturing. The assemblies are available in two styles: the TFA3 has a high-flow, compact design, for use where space is limited; the TFA6 is designed for applications where higher flow capacity is desired.
- 316L stainless steel electropolished housing
- All-fluoro-polymer filter cartridge
- High temperature and pressure capabilities
- 100% integrity tested
- Cleanroom manufactured and packaged
- 100% helium leak tested
- Minimized packaging reduces waste while maintaining product purity
Specifications
Materials
- Medium: PTFE
- Support:
- TFA3: None
- (S)TFA6: fluoro-polymer
- Core and end caps: PFA
- O-ring:
- TFA3: FEP encapsulated fluorocarbon
- (S)TFA6: None
Removal Rating1
- ≥ 3 nm
Connections
- 1⁄4 in., 1⁄2 in. or 3⁄4 gasket seal (VCR2 or compatible)
- 1⁄4 in., 3⁄8 in. or 1⁄2 in. compression fittings
Operating Conditions
- Maximum operating pressure
- TFA3: 20.7 MPa at 122 °C / 3,000 psig at 250 °F
- (S)TFA6: 5.2 MPa at 140 °C / 750 psig at 284 °F
- Maximum allowable forward differential pressure
- TFA3: 0.6 MPa at 21 °C / 80 psid at 70 °F
- (S)TFA6: 0.7 MPa at 20 °C / 100 psid at 68 °F
- Maximum allowable reverse differential pressure
- TFA3: 0.3 MPa at 21 °C / 50 psid at 70 °F
- (S)TFA6: 0.3 MPa at 20 °C / 50 psid at 68 °F
- EU Pressure Equipment Directive:
- TFA3: Assemblies have been evaluated and designed using SEP per the European Union's Pressure Equipment Directive 97/23/EC and are not CE marked.
- (S)TFA6: Assemblies have been evaluated for compliance with the European Union's Pressure Equipment Directive 97/23/EC and are CE marked.
Leak Rating
- 100% helium leak tested to 10-9 atm-cm3/s
1 Particle rating is based on laboratory testing with NaCl aerosol.
2 VCR is a registered trademark of Swagelok Company.
Performance
Pressure Drop vs. Gas Flow Rate
TFA3VMM4
TFA3VMM68ELBJ
TFA6VMM4 / STFA6SM4
TFA6VMM8 / TFA6VMM12 / STFA6SM8
Type
Filter Capsules
Application
Process gas filtration
Additional Information
Nominal Dimensions
TFA3
TFA6 / STFA6
Ordering Information
Part Number | Description | |
TFA3VMM4 | 1⁄4 in. gasket seal, (VCR or compatible) male / male | 84 / 3.31 |
TFA3VMM68ELBJ | 3⁄8 or 1⁄2 in gasket seal, (VCR or compatible) male / male | 127 / 5 |
TFA6VMM4 | 1⁄4 in. gasket seal, (VCR or compatible) male / male | 127 / 5 |
TFA6VMM8 | 1⁄2 in. gasket seal, (VCR or compatible) male / male | 127 / 5 |
TFA6VMM12 | 3⁄4 in. gasket seal, (VCR or compatible) male / male | 140 / 5.5 |
STFA6SM4 | 1⁄4 in. compression seal, (Swagelok or compatible) male / male | 113 / 4.4 |
STFA6SM6 | 3⁄8 in. compression seal, (Swagelok or compatible) male / male | 118 / 4.6 |
STFA6SM8 | 1⁄2 in. compression seal, (Swagelok or compatible) male / male | 119 / 4.7 |
Unit conversion: 100 kilopascals = 1 bar