Fluorodyne® II JSD Filter Cartridges For Enhanced Microbial Retention product photo Primary L

Fluorodyne® II JSD Filter Cartridges For Enhanced Microbial Retention

Fluorodyne II filter cartridges are hydrophilic membrane filters designed for reliable retention of bacteria in the final filtration of bottled water.

Description

The Fluorodyne II JSD filter was developed and validated to provide enhanced, secure and reliable removal of microorganisms from bottled water. The cartridge is constructed from serial layers of 0.2 and 0.1 micron polyvynilydine fluoride (PVDF) membrane. The single open ended (SOE) configuration is designed to fit into sanitary housings to ensure effective microbial removal and assembly integrity.

The Fluorodyne II JSD filter is suitable for exposure to in situ steam sanitization cycles for longer service life.

This filter is integrity testable. An in-situ and non-destructive integrity test can provide assurance of filter performance within minutes. Integrity tests help manufacturers avoid costly issues such as product contamination, product losses, reprocessing and production delays, as well as satisfying auditor requirements.

Learn more about the importance of Integrity Testing and microbial filtration

Media

  • Hydrophilic, easy to wet and integrity test
  • Fixed pores, non-shedding, resin and surfactant free

Element

  • Multiple adapter options for installation into sanitary housings
  • Repeated sanitization/sterilization capability for economical operation
  • Individually serialized for full traceability

Quality

  • Cartridges produced in a controlled environment
  • Manufactured according to ISO 9001:2000 certified Quality Management System

Microbial Removal Rating

Fluorodyne II JSD filter cartridges, passing an appropriate integrity test, provide a sterile effluent when challenged with Brevundimonas diminuta at ≥1 x 107 CFU per cm2 of effective filtration area.

Fluorodyne II JSD filter cartridges passing the appropriate Forward Flow integrity test have also been shown in laboratory tests to give titre reductions of typically 108 when challenged with Acholeplasma laidlawii ATCC28206 at a challenge level of 107 per cm2 filtration area.

Materials of Construction

 
Filter Medium Hydrophilic polyvinylidene fluoride
Support and Drainage Polypropylene
Core, Cage, End Cap and Fin End Polypropylene
Adaptor Polypropylene with internal stainless steel reinforcing ring
O-ring Seal Silicone elastomer (H4)
 


Contact Us
* 需要的

描述

Fluorodyne II filter cartridges are hydrophilic membrane filters designed for reliable retention of bacteria in the final filtration of bottled water.

Description

The Fluorodyne II JSD filter was developed and validated to provide enhanced, secure and reliable removal of microorganisms from bottled water. The cartridge is constructed from serial layers of 0.2 and 0.1 micron polyvynilydine fluoride (PVDF) membrane. The single open ended (SOE) configuration is designed to fit into sanitary housings to ensure effective microbial removal and assembly integrity.

The Fluorodyne II JSD filter is suitable for exposure to in situ steam sanitization cycles for longer service life.

This filter is integrity testable. An in-situ and non-destructive integrity test can provide assurance of filter performance within minutes. Integrity tests help manufacturers avoid costly issues such as product contamination, product losses, reprocessing and production delays, as well as satisfying auditor requirements.

Learn more about the importance of Integrity Testing and microbial filtration

Media

  • Hydrophilic, easy to wet and integrity test
  • Fixed pores, non-shedding, resin and surfactant free

Element

  • Multiple adapter options for installation into sanitary housings
  • Repeated sanitization/sterilization capability for economical operation
  • Individually serialized for full traceability

Quality

  • Cartridges produced in a controlled environment
  • Manufactured according to ISO 9001:2000 certified Quality Management System

Microbial Removal Rating

Fluorodyne II JSD filter cartridges, passing an appropriate integrity test, provide a sterile effluent when challenged with Brevundimonas diminuta at ≥1 x 107 CFU per cm2 of effective filtration area.

Fluorodyne II JSD filter cartridges passing the appropriate Forward Flow integrity test have also been shown in laboratory tests to give titre reductions of typically 108 when challenged with Acholeplasma laidlawii ATCC28206 at a challenge level of 107 per cm2 filtration area.

Materials of Construction

 
Filter Medium Hydrophilic polyvinylidene fluoride
Support and Drainage Polypropylene
Core, Cage, End Cap and Fin End Polypropylene
Adaptor Polypropylene with internal stainless steel reinforcing ring
O-ring Seal Silicone elastomer (H4)
 

Specifications

Technical Information

Operating Characteristics in Compatible Fluids1

 
Maximum Differential Pressure Operating Temperature
5.3 bard (76.9 psid) (forward pressure) 50 °C (122 °F)
3.4 bard (49.3 psid) (forward pressure) 80 °C (176 °F)2
300 mbard (4.4 psid) (reverse pressure) In normal operation or in situ steam sterilization
 
1 Compatible fluids are defined as those which do not swell, soften or attack any of the filter components.
2 Maximum operating temperature is 90 °C.

Sterilization and Sanitization

Fluorodyne II JSD filters may be repeatedly steam sterilized.

 
Media Temperature Cumulative Time/Cycles3
Steam 140 °C (284 °F) 5 hours /5 cycles
Steam 125 °C (257 °F) 30 hours / 30 cycles
Steam (reverse) 125 °C (257 °F) 5 hours / 5 cycles
 
3 Measured under laboratory test conditions. The actual cumulative time depends on the process conditions.

Pressure Drop vs. Liquid Flow Rate4

4.2 liters per minute @ 100 mbar
0.76 US gpm @ 1 psi

4 Typical initial clean media differential pressure (ΔP) per 250 mm (10”) cartridge for water at 20 °C (68 °F); viscosity 1 centipoise. For 508, 762 mm and 1016 mm configurations divide the differential pressure by 2, 3, and 4 respectively.

Segments

Dairy, Food and Ingredients, Pet Food, Food Safety, Quality Control

Type

Filter Cartridges

Use

Diagnostics, Monitoring, Testing

Ordering Information

This is a guide to the Part Numbering structure only. For specific options, please contact Pall.

Table 1: Nominal Length

 
Code Description
1 254 mm (10")
2 508 mm (20")
3 762 mm (30")
4 1016 mm (40")
 

Table 2: Adaptor

 
Code Description
7 SOE – single end with fin end, 2 locking tabs and external 226 O-rings
28* SOE – single open end with fin end, 3 locking tabs and external 222 O-rings
 
* Available in AB3 only

检查

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.