9681 Series Filter Assemblies product photo Primary L

9681 Series Filter Assemblies

Supralon™ deliver consistent, high level fluid system protection across all applications, regardless of severity. Supralon filters feature BetaX(C) >2000 filter efficiency, low pressure drop and long service life.

Features

  • Flows to 565 lpm (150 US gpm)
  • Pressures to 420 bar (6100 psi)
  • Port size 1 14 in. & 1 12 in.


Contact Us
* 需要的

描述

Supralon™ deliver consistent, high level fluid system protection across all applications, regardless of severity. Supralon filters feature BetaX(C) >2000 filter efficiency, low pressure drop and long service life.

Features

  • Flows to 565 lpm (150 US gpm)
  • Pressures to 420 bar (6100 psi)
  • Port size 1 14 in. & 1 12 in.

Specifications

Notes and Specifications
Filter Housing

  • Fatigue Pressure Rating:
    275 bar (4000 psi) per NFPA T2.6.1 R2-2001 Cat C/90
  • Typical Burst Pressure:
    1,260 bar (18,000 psi)
  • Filter Element Collapse Pressure:
    207 bard (3000 psid)
  • Fluid Compatibility:
    Compatible with all petroleum oils and most water glycols, water-oil emulsions, and synthetic hydraulic and lubricating fluids
  • Temperature Range:
    -43˚ C to 107˚ C (-45˚ F to 225˚ F) – Nitrile seals
    -29˚ C to 120˚ C (-20˚ F to 225˚ F) – Fluorocarbon seals
    60˚ C (140˚ F) maximum in HWCF or water glycols
  • Bypass Valve Setting:
    Non-bypass
  • Indicator Pressure Setting:
    7 bard (100 psid)
  • Housing Materials of Construction:
    Ductile iron head; steel bowl

Dimensional Drawing

Dimensions in mm (inches)

Performance

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.

Housing pressure drop is directly proportional to specific gravity.

Element Pressure Drop

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9.

9601 Series Element
DP Factors (psid/gpm)

Length CP CT
8” 0.52 0.12
13” 0.32 0.08
16” 0.25 0.07

Type

Housings, Vessels, or Assemblies

Ordering Information

For new installations, select one complete part number from each section below

Section 1 Housing P/N:

Note: Pall filter housings are supplied without filter elements or filter change out warning devices. Never operate the filter housing unless a filter element is fitted and all warning device ports are sealed.

Housing part number designates indicator port is fitted with a plastic shipping plug.

Part Number Part Number
HH9681C20SW1 HZ9681C20UW1
HH9681C20TW1 HZ9681C24TW1
HH9681C24SW1 HZ9681G20UW1
HH9681C24UW1 HZ9681K20SW1
HH9681G20SW1 HZ9681K20TW1
HH9681K20TW1 HZ9681S20SW1
HH9681K20UW1 HZ9681S20TW1
HH9681S20SW1
HH9681S20TW1
HH9681S20UW1

Part Number (Description) Breakdown
HH = housing with nitrile seals
HZ = housing with fluorocarbon seals
9681 = 9681 Series housing
C20 = 1¼” BSP ISO 228 threads
C24 = 1½” BSP ISO 228 threads
G20 = 1¼” ISO 6162 split flange ports (400 bar/5800 psi max pressure)
K20 = 1¼” Top Manifold Mount
S20 = 1¼” Side Manifold Mount
S = 8” nominal length
T = 13” nominal length
U = 16” nominal length
W = Non-bypass
1 = 1 indicator warning device port

Section 2 Differential Pressure Indicator

HC9601 F [Table 1] [Table 2] Z Table 1:
Filter Performance Ratings
Code ßx(c) ≥1000 per ISO 16889
CP 5
CT 15

Table 2:
Length Options
Code Description
8 8” nominal length
13 13” nominal length
16 16” nominal length

Section 3 Differential Pressure Indicator

P/N: RC [Table 3] Z 097 Z [Table 4]

Note: If no Differential Pressure Indicator is selected, ‘B’ type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the shipping plug.

Note: Z indicates fluorocarbon seals are standard. Other options are available; contact Pall.


Table 3: Indicator Options
Code Brass Option Indicator
A218M Electrical switch (SPDT) with Hirschmann connector
A218R Electrical switch (SPDT) with Hirschmann connector with Red and Green LED indicators
A219D Visual indicator

Code Stainless Steel Option Indicator
778N Visual filter with thermal lockout
861C Electrical switch (SPDT) with Hirschmann connector
771B Electrical switch (SPDT) with 3-pin

Table 4: Differential Pressure Indicator Material
Code Description
Omit If Brass Indicator is selected in Table 3
SS If Stainless Steel Indicator is selected in Table 3 (recommended for high pressure applications with pressure > 200 bar (3000 psi)

检查

Earn 10% off* your next order online by leaving a review of this product. Please login to your account to leave a review. We appreciate and value your feedback.

*Subject to Terms and Conditions.