6300 Series Filter Assemblies product photo Primary L

6300 Series Filter Assemblies

Flows to 120 gpm (450 L/min)
Pressures to
250 psi (17 bar)
Port sizes:
1-1/4" and 1-1/2"

Please Note:
The 6300 series filter assemblies are no longer available and are being replaced with Ultipleat® UT319 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.


Contact Us
* 需要的

描述

Flows to 120 gpm (450 L/min)
Pressures to
250 psi (17 bar)
Port sizes:
1-1/4" and 1-1/2"

Please Note:
The 6300 series filter assemblies are no longer available and are being replaced with Ultipleat® UT319 Filter Assemblies

All replacement filter elements, differential pressure indicators and sealkits remain available for this series. See 'Ordering Information' tab above for details of spares.

Specifications

Maximum Allowable Working Pressure:

250 psi (17 bar)

Fatigue Pressure Rating:

Rated Fatigue pressure: 250 psi (17 bar) 107 cycles per NFPA T2.6.1 - 1974

Temperature Range:

Nitrile seals -45°F to 225°F (-43°C to 107°C)
Fluorocarbon seals -20°F to 250°F (-29°C to 120°C)
140°F (60°C) maximum in HWCF or water-glycol fluids

Dry Weights:

S length– 18.5 lbs. (8.4 kg)
T length– 20.0 lbs. (9.1 kg)
U length– 23.5 lbs. (10.7 kg)
V length– 27.0 lbs. (12.3 kg)

Filter Element Collapse Pressure:

150 psid (10 bar)

Caution:

120 psi (8 bar) maximum for non-bypass valve options (prevents possible filter element collapse)

Dimensional Drawings


 


   

 

 



 

Performance

Figure 1. Housing Pressure Drop using fluid with 0.9 S.G.
Housing Pressure drop is directly proportional to specific gravity.


 
 
Figure 2. Bypass Valve Pressure Drop using fluid with 0.9 S.G.
Bypass valve pressure drops are directly proportional to specific gravity.


 

Element Pressure Drop Factor

Multiply actual flow rate times factor to determine pressure drop with fluid at 150 SUS (32 cSt), 0.9 S.G.
Correct for other viscosities by multiplying new viscosity in SUS/150 x new S.G/0.9.

 
6300 Series Element P factor (psid/gpm)
 

Length

DP
DN
DS
DT
         
8"
0.29
0.18
0.13
0.09
         
13"
0.19
0.10
0.08
0.07
         
16"
0.14
0.08
0.06
0.05
         
26"
0.11
0.05
0.04
0.03
 

 

Segments

General Industrial, Mining, Mining, Mining, Mining, Mining, Mining, Mining, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Primary Metals, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, Pulp & Paper, General Industrial, General Industrial, General Industrial, General Industrial

Type

Housings, Vessels, or Assemblies

Ordering Information

Assembly P/N:     

H

6300

 

 

Table1

 

Table2
Table3
Table4
Table5
Table6
Table7
Table8
Table9

Element P/N:       

HC

6300F

 

 

 

 

 

 
Table4
Table5
Table1

 

 

 


 

Note: Choose from the options in the following tables to compile the specific Product Number.

TABLE 1: SEAL OPTIONS
 
CodeSeals
   
H Nitrile
   
Z Fluorocarbon
 

 
TABLE 2: PORT STYLE OPTIONS
 
Code
Port Style
   
A
SAE J514 straight thread
   
B
NPT
   
D
Flange SAE J518c-Code 61
 
 

 

TABLE 3: INLET PORT SIZE OPTIONS

 
Code
Size
   
20
1-1/4"
   
24
1-1/2"
 
 


 

TABLE 4: FILTER ELEMENT OPTIONS
 
Code
ßx  200
ßx(c)=1000
     
DP
3
5
     
DN
6
7
     
DS
12
12
     
DT
25
22
 
 

 

TABLE 5: LENGTH OPTIONS*
 
Assembly Code
Element Code**
   
S
8
   
T
13
   
U
16
   
V
26
 
* Use code in second column for element part no.
** Nominal length in inches.

 

 
TABLE 6: BYPASS VALVE OPTIONS
 
Code
Description
   
A
25 psid
   
B
50 psid
   
W
Non-bypass
   
8
25 psid with ABFV*
   
9
50 psid with ABFV
   

V

Non-bypass with ABFV
 
* ABFV- Anti-backflow valve.



 

TABLE 7: DIFFERENTIAL PRESSURE DEVICE OPTIONS
 
Code
Description
   
PM
Visual indicator with thermal lockout
   
DM
Visual indicator with no thermal lockout
   
LL
Electrical switch (SPDT) with 6" leads
   
TL
Electrical switch with DIN connector
   
ML
'TL' type switch with matching wiring cap
   
SL
Electrical switch with MS receptacle
   
BL
Plug in place of indicator
   
PL
Same as PM but with plastic body
   
DL
Same as DM but with plastic body
 

Indicator and switch pressure settings.
16 psid with "A" and "8" bypass valve.
35 psid with "W," "V," "B," and "9" option.



 

TABLE 8: SECONDARY PORT OPTIONS
 
Code
Port Option
Port Size
     
S
Port machined
1"
     
N
Non-machined
-
 

Port opposite main inlet in style consistent with main inlet port (see Table 2) except that "A" style secondary port is used with "D" style main inlet port.



 

TABLE 9: AUXILIARY PORT OPTIONS
 
Code
Port Option
Port Size
     
R
Right side*
3/4"
     
L
Left side*
3/4"
     
B
Both
3/4"
     
N
Non-machined
-
 
* Left or right side when facing inlet port. Port style consistent with main inlet port (See Table 2), except that "A" style auxiliary port(s) is used with "D" style main inlet port.

 